Printhead Card Managers | PHCM-DG2
PHCM-DG2 – Ethernet
GIS Inkjet Operating System
The PHCM-DG2 is the latest hardware component of the GIS Inkjet Operating System.
It enables a standard Windows PC to drive multiple industrial inkjet printheads via Ethernet in Single Pass, Scanning XY and custom systems. The PHCM-DG2 also supports drop watching.
Complete Printhead Control
The PHCM-DG2 provides read and write access to all available OEM printhead settings including temperature control, voltage and waveform settings, binary and greyscale calibration.
Drop Placement Control
The Advanced Encoder Manager System (AEMS) supports industry standard encoders and product detect / print go signals and provides per-printhead encoder divide and sub-pixel adjust, delivering complete drop placement control and repeatability.
Features
PC to PHCM Comms (Mb/s) | Ethernet 1Gb |
Max. Memory (MB) | n/a |
Channels | 6, up to 1.3Gbps per channel |
Encoder | RS422 & TTL 32 Quad, isolated high speed |
Product Detect | RS422 & TTL, up to 512 deep |
Maximum System Size | No Limit |
Cable length | 100m, RJ45/CAT 6A/Fibre |
Encoder and Product Detect Go Daisy Chain | Yes, RS422, NPN & TTL (3.3V up to 24V) |
Connectivity
The PHCM-DG2 is a component of the GIS Inkjet Operating System. It is designed to drive any manufacturer’s printhead using GIS Printhead Cards.
Performance
Each printhead is driven by a dedicated high speed channel capable of delivering print data on demand in the most demanding of applications.
High speed on-board RAM provides ample buffering for wide-format and single pass systems, allowing the specialised software drivers to deliver continuous static and variable data streams to the printheads.
Advanced Applications
With the power to simultaneously drive multiple printhead technologies off the same system at different resolutions, the PHCM-DG2 opens up a world of possibilities for printer development and manufacturing.
Download Datasheets
GIS Printhead Card Managers